96 research outputs found

    Intrasubject multimodal groupwise registration with the conditional template entropy

    Get PDF
    Image registration is an important task in medical image analysis. Whereas most methods are designed for the registration of two images (pairwise registration), there is an increasing interest in simultaneously aligning more than two images using groupwise registration. Multimodal registration in a groupwise setting remains difficult, due to the lack of generally applicable similarity metrics. In this work, a novel similarity metric for such groupwise registration problems is proposed. The metric calculates the sum of the conditional entropy between each image in the group and a representative template image constructed iteratively using principal component analysis. The proposed metric is validated in extensive experiments on synthetic and intrasubject clinical image data. These experiments showed equivalent or improved registration accuracy compared to other state-of-the-art (dis)similarity metrics and improved transformation consistency compared to pairwise mutual information

    Automated motion analysis of bony joint structures from dynamic computer tomography images: A multi-atlas approach

    Get PDF
    Dynamic computer tomography (CT) is an emerging modality to analyze in-vivo joint kinematics at the bone level, but it requires manual bone segmentation and, in some instances, landmark identification. The objective of this study is to present an automated workflow for the assessment of three-dimensional in vivo joint kinematics from dynamic musculoskeletal CT images. The proposed method relies on a multi-atlas, multi-label segmentation and landmark propagation framework to extract bony structures and detect anatomical landmarks on the CT dataset. The segmented structures serve as regions of interest for the subsequent motion estimation across the dynamic sequence. The landmarks are propagated across the dynamic sequence for the construction of bone embedded reference frames from which kinematic parameters are estimated. We applied our workflow on dynamic CT images obtained from 15 healthy subjects on two different joints: thumb base (n = 5) and knee (n = 10). The proposed method resulted in segmentation accuracies of 0.90 ± 0.01 for the thumb dataset and 0.94 ± 0.02 for the knee as measured by the Dice score coefficient. In terms of motion estimation, mean differences in cardan angles between the automated algorithm and manual segmentation, and landmark identification performed by an expert were below 1◦. Intraclass correlation (ICC) between cardan angles from the algorithm and results from expert manual landmarks ranged from 0.72 to 0.99 for all joints across all axes. The proposed automated method resulted in reproducible and reliable measurements, enabling the assessment of joint kinematics using 4DCT in clinical routine

    Anion redox as a means to ferive layered manganese oxychalcogenides with exotic intergrowth structures

    Get PDF
    Topochemistry enables step-by-step conversions of solid-state materials often leading to metastable structures that retain initial structural motifs. Recent advances in this field revealed many examples where relatively bulky anionic constituents were actively involved in redox reactions during (de)intercalation processes. Such reactions are often accompanied by anion-anion bond formation, which heralds possibilities to design novel structure types disparate from known precursors, in a controlled manner. Here we present the multistep conversion of layered oxychalcogenides Sr2MnO2Cu1.5Ch2 (Ch = S, Se) into Cu-deintercalated phases where antifluorite type [Cu1.5Ch2]2.5- slabs collapsed into two-dimensional arrays of chalcogen dimers. The collapse of the chalcogenide layers on deintercalation led to various stacking types of Sr2MnO2Ch2 slabs, which formed polychalcogenide structures unattainable by conventional high-temperature syntheses. Anion-redox topochemistry is demonstrated to be of interest not only for electrochemical applications but also as a means to design complex layered architectures

    Registration of magnetic resonance and computed tomography images in patients with oral squamous cell carcinoma for three-dimensional vir

    Get PDF
    The aim of this study was to evaluate and present an automated method for registration of magnetic resonance imaging (MRI) and computed tomography (CT) or cone beam CT (CBCT) images of the mandibular region for patients with oral squamous cell carcinoma (OSCC). Registered MRI and (CB)CT could facilitate the three-dimensional virtual planning of surgical guides employed for resection and reconstruction in patients with OSCC with mandibular invasion. MRI and (CB)CT images were collected retrospectively from 19 patients. MRI images were aligned with (CB)CT images employing a rigid registration approach (stage 1), a rigid registration approach using a mandibular mask (stage 2), and two non-rigid registration approaches (stage 3). Registration accuracy was quantified by the mean target registration error (mTRE), calculated over a set of landmarks annotated by two observers. Stage 2 achieved the best registration result, with an mTRE of 2.5 ± 0.7 mm, which was comparable to the inter- and intra-observer variabilities of landmark placement in MRI. Stage 2 was significantly better aligned compared to all approaches in stage 3. In conclusion, this study demonstrated that rigid registration with the use of a mask is an appropriate image registration method for aligning MRI and (CB)CT images of the mandibular region in patients with OSCC

    Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: The LUNA16 challenge

    Get PDF
    Automatic detection of pulmonary nodules in thoracic computed tomography (CT) scans has been an active area of research for the last two decades. However, there have only been few studies that provide a comparative performance evaluation of different systems on a common database. We have therefore set up the LUNA16 challenge, an objective evaluation framework for automatic nodule detection algorithms using the largest publicly available reference database of chest CT scans, the LIDC-IDRI data set. In LUNA16, participants develop their algorithm and upload their predictions on 888 CT scans in one of the two tracks: 1) the complete nodule detection track where a complete CAD system should be developed, or 2) the false positive reduction track where a provided set of nodule candidates should be classified. This paper describes the setup of LUNA16 and presents the results of the challenge so far. Moreover, the impact of combining individual systems on the detection performance was also investigated. It was observed that the leading solutions employed convolutional networks and used the provided set of nodule candidates. The combination of these solutions achieved an excellent sensitivity of over 95% at fewer than 1.0 false positives per scan. This highlights the potential of combining algorithms to improve the detection performance. Our observer study with four expert readers has shown that the best system detects nodules that were missed by expert readers who originally annotated the LIDC-IDRI data. We released this set of additional nodules for further development of CAD systems

    Intensity-Based Deformable Registration: Introduction and Overview

    No full text
    International audienceThe purpose of this chapter is to give an introduction to intensity-based deformable image registration and present a brief overview of the state-of-the-art. First, we lay out the basic principles of deformable registration. Next, the key components of the registration framework are discussed in detail and two popular algorithms for deformable registration are described as an example. We review past studies on respiratory motion estimation for radiotherapy. Finally, we briefly list useful open-source software packages and available image and validation data sets for deformable registration of the thora

    Advances in deformable image registration of thoracic 4D CT

    No full text
    International audienc
    • …
    corecore